Motor controls
Easy adjustable controllers for brushed and brushless dc motors.
![](/fileadmin/_processed_/a/c/csm_06.04.001_7e6ca7edf3.jpg)
Maxi-M-8-30 (06.04.001) Nominal current : 8 A
Not recommended for new designs. Possible replacement: 06.04.201
Characteristics
dynamic brake
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/9/7/csm_06.04.002_c44799d0a2.jpg)
Maxi-MW-8-30 (06.04.002) Nominal current : 8 A
Not recommended for new designs. Possible replacement: 06.04.202
Characteristics
rotation reversal
dynamic brake
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/9/9/csm_06.04.008_68fe27c681.jpg)
M-S-6-30 (06.04.008) Nominal current : 6 A
Not recommended for new designs. Possible replacement: 06.38.007
Characteristics
speed control
start ramp
stop ramp
dynamic brake
manual adjustment elements
analog input
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/d/2/csm_06.04.012_d02836643e.jpg)
Midi-M-8-30 (06.04.012) Nominal current : 8 A
Not recommended for new designs. Possible replacement: 06.04.212
Characteristics
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/9/7/csm_06.04.002_c44799d0a2.jpg)
Maxi-MW-8-12 (06.04.014) Nominal current : 8 A
Illustration similar
Not recommended for new designs. Possible replacement: 06.04.202
Characteristics
rotation reversal
dynamic brake
Voltage
12 VDC
Connection
screw terminals
![](/fileadmin/_processed_/0/1/csm_06.04.016_3e6a8dc041.jpg)
Maxi-MR-5-30 (06.04.016) Nominal current : 6 A
This product is no longer available. Possible replacement:: 06.34.001
Characteristics
rotation reversal
speed control
start ramp
dynamic brake
analog input
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/0/1/csm_06.04.016_3e6a8dc041.jpg)
Maxi-MR-5-12 (06.04.019) Nominal current : 5 A
This product is no longer available. Possible replacement:: 06.34.006
Characteristics
rotation reversal
speed control
start ramp
dynamic brake
analog input
Voltage
12 VDC
Connection
screw terminals
![](/fileadmin/_processed_/5/0/csm_06.04.025_f780a72bed.jpg)
M-MWI-5-30 (06.04.025) Nominal current : 5 A
Not recommended for new designs. Possible replacement: 06.34.008
Characteristics
rotation reversal
dynamic brake
overcurrent shutdown
manual adjustment elements
Digital output
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/0/e/csm_06.04.031_cee396c128.jpg)
M-4Q-6-30 (06.04.031) Nominal current : 6 A
+- 10 V analog input
Not recommended for new designs. Possible replacement: 06.38.007
Characteristics
rotation reversal
speed control
IxR compensation
dynamic brake
overcurrent limitation
manual adjustment elements
analog input
Digital output
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/0/e/csm_06.04.031_cee396c128.jpg)
M-4Q-6-48 (06.04.032) Nominal current : 6 A
Illustration similar
+- 10 V analog input
Not recommended for new designs. Possible replacement: 06.38.007
Characteristics
rotation reversal
speed control
IxR compensation
dynamic brake
overcurrent limitation
manual adjustment elements
analog input
Digital output
Voltage
48 VDC
Connection
screw terminals
![](/fileadmin/_processed_/5/0/csm_06.04.025_f780a72bed.jpg)
M-MWI-5-12 (06.04.046) Nominal current : 5 A
Illustration similar
Not recommended for new designs. Possible replacement: 06.34.006
Characteristics
rotation reversal
dynamic brake
overcurrent shutdown
manual adjustment elements
Digital output
Voltage
12 VDC
Connection
screw terminals
![](/fileadmin/_processed_/5/0/csm_06.04.025_f780a72bed.jpg)
M-MWI-1-30 (06.04.049) Nominal current : 1 A
Illustration similar
Not recommended for new designs. Possible replacement: 06.34.017
Characteristics
rotation reversal
dynamic brake
overcurrent shutdown
manual adjustment elements
Digital output
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/a/b/csm_06.04.059_498db4d013.jpg)
M-1Q-5-30 (06.04.059) Nominal current : 5 A
Not recommended for new designs. Possible replacement: 06.34.013
Characteristics
rotation reversal
speed control
IxR compensation
dynamic brake
manual adjustment elements
analog input
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/c/4/csm_06.04.066_35dfd7a9fa.jpg)
M-BL-10-24 (06.04.066) Nominal current : 10 A
Not recommended for new designs. Possible replacement: 06.38.001
Characteristics
rotation reversal
speed control
dynamic brake
overcurrent shutdown
manual adjustment elements
analog input
Digital output
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/a/9/csm_06.04.075_6af11d15d5.jpg)
M-4Q-10-30 (06.04.075) Nominal current : 10 A
Not recommended for new designs. Possible replacement: 06.38.007
Characteristics
rotation reversal
speed control
IxR compensation
start ramp
dynamic brake
overcurrent limitation
overcurrent shutdown
manual adjustment elements
analog input
Digital output
Voltage
24 VDC
Connection
screw terminals
![](/fileadmin/_processed_/a/9/csm_06.04.075_6af11d15d5.jpg)
M-4Q-10-48 (06.04.083) Nominal current : 10 A
Illustration similar
Not recommended for new designs. Possible replacement: 06.38.007
Characteristics
rotation reversal
speed control
IxR compensation
start ramp
dynamic brake
overcurrent limitation
overcurrent shutdown
manual adjustment elements
analog input
Digital output
Voltage
48 VDC
Connection
screw terminals
![](/fileadmin/_processed_/4/2/csm_06.04.085_b378d0d25d.jpg)
M-4Q-5-30 (06.04.085) Nominal current : 5 A
Not recommended for new designs. Possible replacement: 06.34.002
Characteristics
rotation reversal
speed control
IxR compensation
start ramp
dynamic brake
overcurrent limitation
overcurrent shutdown
manual adjustment elements
analog input
Digital output
Voltage
24 VDC
Connection
screw terminals